The Design Water Flow Measurement with Ultra Sonic Sensor

Authors

  • Jamaaluddin Jamaaluddin Universitas Muhammadiyah Sidoarjo
  • Ali Akbar Universitas Muhammadiyah Sidoarjo
  • Khoiri Universitas Muhammadiyah Sidoarjo

Keywords:

ulltrasonic; Flowmeter; PDAM

Abstract

Human life in the world cannot be separated from the need for water. This water utilization can be maximized by implementing water use management. To carry out water usage management, precise measuring instruments are needed and continuous and up-to-date observations are made. So the measurement of water discharge needs to be done carefully and automatically. In this system the flow meter readings use ultrasonic. The reading results are obtained on the microcontroller. The output of this microcontroller is displayed through a display that can be read directly. Besides that, the reading results are also sent via modbus to an android phone or other receiving system. To determine the precision of the measurement, it is necessary to compare it with a manual flow meter. The process of comparing the measurement results with ultrasonic with manual measurements is carried out by installing a series between ultrasonic and manual meters. After that, the remote delivery process is carried out using modbus. The measurement results of the comparison of ultrasonic and manual meters show an error value of 6.45%. This tool can be used as a means of controlling water consumption and the results can be transmitted over long distances.

References

Y. P. Heston and A. Pasawati, “Analisis Faktor Penyebab Kehilangan Air PDAM,” Temu Ilm. IPLBI 2016, no. 1, p. 6 hal, 2016.

D. Nugraha, “Studi Kehilangan Air Akibat Kebocoran Pipa Pada Jalur Distribusi Pdam Kota Magelang (Studi Kasus: Perumahan Armada Estate Dan Depkes, Kramat Utara Kecamatan Magelang Utara ),” J. Presipitasi, vol. 7, no. 2, pp. 71-76–76, 2010, doi: 10.14710/presipitasi.v7i2.71-76.

D. J. Kuncoro, “Studi Deskriptif tentang Kualitas Pelayanan Penanganan Keluhan Pelanggan Perusahaan Daerah Air Minum Kota Surabaya,” J. Univ. Airlangga, vol. 4 No.2, pp. 220–229, 2016.

H. Jawas, N. M. A. E. D. Wirastuti, and W. Setiawan, “Prototype Pengukuran Tinggi Debit Air Pada Bendung Dengan Menggunakan Sensor Ultrasonik Berbasis Arduino Mega 2560,” J. SPEKTRUM, vol. 5, no. 1, p. 1, 2018, doi: 10.24843/spektrum.2018.v05.i01.p01.

A. Mustika and B. Rosa, “Penggunaan Sensor Ultrasonik sebagai Pendeteksi Ketinggian Air di Sungai,” Pros. Ind. Res. Work. Natl. Semin., vol. 2, no. November 2017, pp. 143–147, 2011.

T. Supriyadi, “Penggunaan Sensor Ultrasonik Sebagai Pendeteksi Ketinggian Air Sungai Pada Sistem Peringatan Dini,” Ind. Res. Work. Natl. Semin., pp. 143–147, 2011.

S. Idris, “Perancangan Alat Ukur Kecepatan Air Pada Pipa Dengan Metode Efek Doppler Berbasis Raspberry Pi,” 2017.

M. Ichwan, M. G. Husada, and M. Iqbal Ar Rasyid, “Pembangunan Prototipe Sistem Pengendalian Peralatan Listrik Pada Platform Android,” J. Inform., vol. 4, no. 1, pp. 13–25, 2013.

R. D. Riupassa, H. Raflis, and Hendro, “Optimasi Nilai Konstanta Kalibrasi Pada Water Flow Sensor Yf-S201,” J. Tek. Inform., pp. 2–6, 2017, [Online]. Available: https://ejournal.sttbandung.ac.id/assets/file/RobiDany.pdf

A. Suharjono, L. N. Rahayu, and R. Afwah, “Aplikasi Sensor Flow Water Untuk Mengukur Penggunaan Air Pelanggan Secara Digital Serta Pengiriman Data Secara Otomatis Pada PDAM Kota Semarang,” Tek. Elektro, Politek. negeri Semarang, vol. Vol.13, no. 1, pp. 7–12, 2015.

E. Parameter, “Ultrasonic Ranging Module HC - SR04,” pp. 3–5.

Downloads

Published

2023-07-06

Issue

Section

Articles